Confirmed technical specifications| Ingress protection | IP66 |
|---|
| Dimensions | 202 × 260.8 × 88.53 mm (W × H × D), including the audio-visual alarm, cable gland and sensor housing |
|---|
| Weight | 1.4 kg — 1.6 kg with the audio-visual alarm. |
|---|
| Operating temperature | -20 °C to 55 °C |
|---|
| Sampling method | Diffusion |
|---|
| Display size | 1.7 in |
|---|
| Data storage | > 100,000 records |
|---|
- Standard gas configuration
- 1 gas
- Expanded gas configuration
- No higher gas-count expansion documented
- Typical measurement accuracy
- ≤ ±3% FS; higher-accuracy sensors available
- Response time
- T90 ≤ 30 s
- Recovery time
- ≤ 30 s
- Operating humidity
- 10–95% RH, non-condensing
- Power supply
- 24 V DC; 220 V AC optional
- Signal output
- RS485 Modbus RTU and three-wire 4–20 mA standard; two-wire 4–20 mA optional
- Alarm output
- One dry-contact output standard; two available as an option; local audible and visual alarm optional
- Wireless options
- 433 MHz, LoRa, Wi-Fi, 4G/5G and NB-IoT configurations
- Explosion protection
- Ex db IIC T6 Gb / Ex tb IIIC T80 °C Db
- Standard accessories
- Operating instructions, product conformity document, warranty card, infrared remote control and outer packaging
- Local operation
- 3-key keypad and infrared remote control
- Mounting options
- Wall, L-bracket, base, flange, or vertical-pipe mounting with U-bolt and L-bracket
- Terminal layout
- RS485 (A, B); relay 1 (NC, COM, NO); relay 2 (NO, COM); V, S, G for 24 V DC and 4–20 mA