How to Choose a VOC Gas Detector cover featuring Eranntex BTYQ-MS600-S portable VOC detector, BTYQ-PTM600-S transportable multi-gas analyzer, and TH-2000-OU VOC pretreatment cabinet.
From the technical libraryHow to Choose a VOC Gas Detector: Field Selection

8 of 8 articles

How to Choose a VOC Gas Detector cover featuring Eranntex BTYQ-MS600-S portable VOC detector, BTYQ-PTM600-S transportable multi-gas analyzer, and TH-2000-OU VOC pretreatment cabinet.
Technical guide

How to Choose a VOC Gas Detector: Field Selection

Choose a VOC detector by matching the sensing principle, UV lamp energy, and sample handling to the gas stream. Use a PID for low-ppm exposure and non-methane leak checks, an FID for methane-referenced leak surveys, and an infrared or catalytic bead channel for %LEL, then check for methane or humidity suppressing the PID signal.

Read article
Eranntex technical guide cover: How to Choose a Portable Gas Detector, with the BTYQ-MS104K-S1, BTYQ-MS104K-M and BTYQ-MS400-S portable gas detectors.
Technical guide

How to Choose a Portable Gas Detector for Industrial Sites

Portable gas detectors serve two primary field functions: continuous personal breathing-zone monitoring across a work shift, and remote pre-entry clearance testing before personnel enter an enclosed or stratified space. Passive diffusion instruments suit daily shift wear, where low weight and extended battery life matter most. Motorized pumped instruments are required when sampling air from tanks, utility trenches, and confined spaces before entry.

Read article
Eranntex technical guide cover: How to Plan a Fixed Gas Detection System, with a fixed gas detector and a gas alarm controller.
Technical guide

How to Plan a Fixed Gas Detection System

A fixed gas detection system is designed around the site. Six site facts settle most of the design: the hazard in each area, where gas is released and where it collects, how the areas are laid out and who responds to an alarm, where cables can run, what the environment does to a sensor, and how long the system must keep working without mains power. Channel counts, signal types and controller size follow from those answers, and a generic layout can only be a starting point.

Read article
Eranntex technical guide cover: What does a 4-gas monitor detect? Product photographs of the BTYQ-MS104K-M and BTYQ-MS400-S portable gas detectors.
Technical guide

What Does a 4-Gas Monitor Detect? Gases, Limits & Selection

A standard 4-gas monitor, often called a 4-gas meter, measures oxygen (O₂, % by volume), combustible gas as a percentage of the lower explosive limit (%LEL), hydrogen sulfide (H₂S, ppm) and carbon monoxide (CO, ppm). Those readings match the atmospheric hazards that US confined-space rules require testing for: oxygen outside 19.5–23.5% by volume, flammable gas above 10% of its lower flammable limit, and toxic gas above its exposure limit. A standard 4-gas configuration does not measure CO₂, and a low %LEL reading does not show that solvent vapor is below its exposure limit. When the hazard includes either one, the instrument needs another sensor.

Read article
Eranntex technical guide: High H₂S peak, but low TWA? A magnifying glass inspects an illustrative peak in monitoring records.
Technical guide

High H₂S Peak, Low TWA: What to Check Next

A high hydrogen sulfide (H₂S) peak and a low time-weighted average (TWA) can describe the same monitoring period. A low TWA does not cancel the peak. Check the event time and sampling location, the TWA calculation window and reset history, and the measurement records around the event.

Read article
Eranntex technical guide cover: gas detector quotation checklist, with project requirement sheets, a clipboard and pencil.
Technical guide

Gas Detector Quotation Preparation Checklist

A technical quotation needs the target gases and ranges, simultaneous monitoring requirement, site conditions, sampling approach, interfaces and documents. This checklist shows what each input helps verify.