H2S monitors and hydrogen sulfide detectors

Eranntex offers H2S detection on 15 models: portable single- and multi-gas detectors, transportable units, fixed detectors and an online monitoring system. Start with the task. A detector the worker carries suits areas people enter; a fixed detector watches one point around the clock. Then choose the range: the models below offer H2S from 0–10 ppm up to 0–50,000 ppm, with diffusion or pump sampling.

Where H2S occurs and what it does

Hydrogen sulfide occurs naturally in sewers, manure pits, well water, oil and gas wells and volcanoes, and is produced or used in oil and gas refining, mining, tanning, pulp and paper processing and rayon manufacturing. It is heavier than air and collects in low-lying areas, manholes, sewers and underground vaults. Its rotten-egg smell is not a reliable warning, because after a while at low concentrations, or quickly at high ones, it can no longer be smelled. OSHA lists these short-term effects by concentration:

0.01–1.5 ppm
Odor threshold, when the rotten-egg smell is first noticeable to some people; it becomes more offensive at 3–5 ppm.
2–5 ppm
Prolonged exposure may cause nausea, tearing of the eyes, headaches or loss of sleep; airway problems in some people with asthma.
20 ppm
Possible fatigue, loss of appetite, headache, irritability, poor memory and dizziness.
50–100 ppm
Slight conjunctivitis and respiratory tract irritation after 1 hour; may cause digestive upset and loss of appetite.
100 ppm
Coughing, eye irritation and loss of smell after 2–15 minutes; altered breathing and drowsiness after 15–30 minutes; throat irritation after 1 hour. Symptoms worsen over several hours, and death may occur after 48 hours.
100–150 ppm
Loss of smell (olfactory fatigue or paralysis).
200–300 ppm
Marked conjunctivitis and respiratory tract irritation after 1 hour; pulmonary edema may occur from prolonged exposure.
500–700 ppm
Staggering and collapse in 5 minutes; serious eye damage in 30 minutes; death after 30–60 minutes.
700–1,000 ppm
Rapid unconsciousness or immediate collapse within 1 to 2 breaths; breathing stops and death follows within minutes.
1,000–2,000 ppm
Nearly instant death.

H2S exposure limits

The limits below apply to workplaces in the US and China.

US OSHA, general industry
Never above 20 ppm. One peak of up to 50 ppm for no more than 10 minutes is allowed once per shift, if there is no other measurable exposure.
US OSHA, construction and shipyards
10 ppm averaged over 8 hours.
US NIOSH recommendation
Never above 10 ppm over any 10 minutes. 100 ppm is immediately dangerous to life or health.
China, GBZ 2.1-2019 (mandatory)
Never above 10 mg/m³ (about 7 ppm) at any time during the working day.

Four Questions for H2S Detector Selection

Monitoring task
Will the detector be worn, carried from point to point, or installed in one place? Describe the work and where gas may collect.
Unit and range
What concentration must the detector read? Give the expected concentration and the resolution you need, then compare the ranges in the table below.
Gas configuration
Is H2S the only gas, or must others be watched at the same time? List every gas and range; how many gases a detector holds differs by model.
Sampling conditions
Will gas reach the sensor on its own (diffusion), or must a pump draw it from a tank, pit or manhole? Tell us the sampling point, tubing length, temperature, humidity and any condensation.

Which H2S Models to Start With

Worn by the worker
MS104K-S2 single- or two-gas detector, with H2S ranges from 0–10 ppm at 0.001 ppm resolution.
Checking a space before entry (pumped)
MS104K-L, MS104K-M, MS400-S, MS600-S, MS600-S1 and MS600-S2 portable detectors draw the sample through a pump; the MS104K-M and MS400-S also run on diffusion.
Fixed points watched around the clock
MIC-500S (ranges up to 0–50,000 ppm), MIC-600, MIC-500S-CB and MIC-600-CB fixed detectors; the MIC-600 and MIC-600-CB also carry other gases.
Area monitoring that moves with the work
PTM600-S (pumped) and PTM600-S2 (diffusion) transportable detectors.
Continuous monitoring in mg/m³
TH-2000-OU online monitoring system, 0–10 mg/m³.

H2S measuring ranges by model

Each filled square is a measuring range the model can be configured with. Ranges, sensor combinations and resolution are confirmed for each order.

H2S measuring ranges (ppm), each from 0 to the value shown, offered by each model
Model10501002005002,00010,00020,00050,000Sampling
Portable Gas Detectors
MS104K-LNot offeredNot offeredNot offeredNot offeredNot offeredPump
MS104K-MNot offeredNot offeredNot offeredNot offeredNot offeredDiffusion (standard) or Pump (standard)
MS104K-S1Not offeredNot offeredNot offeredNot offeredNot offeredNot offeredNot offeredNot offeredDiffusion
MS104K-S2Not offeredNot offeredNot offeredNot offeredDiffusion
MS400-SNot offeredNot offeredNot offeredNot offeredNot offeredDiffusion (standard) or Pump (standard)
MS600-SNot offeredNot offeredNot offeredNot offeredNot offeredPump
MS600-S1Not offeredNot offeredNot offeredNot offeredNot offeredPump
MS600-S2Not offeredNot offeredNot offeredNot offeredNot offeredPump
Transportable Gas Detection Systems
PTM600-SNot offeredNot offeredNot offeredNot offeredNot offeredPump
PTM600-S2Not offeredNot offeredNot offeredNot offeredNot offeredDiffusion
Fixed Gas Detectors
MIC-500SNot offeredNot offeredDiffusion
MIC-500S-CBNot offeredNot offeredNot offeredNot offeredNot offeredDiffusion
MIC-600Not offeredNot offeredNot offeredNot offeredDiffusion
MIC-600-CBNot offeredNot offeredNot offeredNot offeredNot offeredDiffusion
H2S measuring ranges (mg/m3), each from 0 to the value shown, offered by each model
Model10Sampling
Gas Monitoring and Analysis Systems
TH-2000-OUDiffusion
Resolution and sampling details by model

ppm ranges

H2S measuring ranges and resolution by model (ppm)
Product modelProduct categoryMeasuring rangeResolutionSamplingProduct link
BTYQ-MS104K-LPortable Gas Detectors
  • 0–10
  • 0–100
  • 0–500
  • 0–2,000
  • 0.01 ppm
  • 0.01 ppm
  • 0.1 ppm
  • 1 ppm
PumpView BTYQ-MS104K-L
BTYQ-MS104K-MPortable Gas Detectors
  • 0–10
  • 0–100
  • 0–500
  • 0–2,000
  • 0.01 ppm
  • 0.01 ppm
  • 0.1 ppm
  • 1 ppm
Diffusion (standard) or Pump (standard)View BTYQ-MS104K-M
BTYQ-MS104K-S1Portable Gas Detectors
  • 0–100
  • 0.01 ppm
DiffusionView BTYQ-MS104K-S1
BTYQ-MS104K-S2Portable Gas Detectors
  • 0–10
  • 0–50
  • 0–100
  • 0–2,000
  • 0–10,000
  • 0.001 ppm
  • 0.01 ppm
  • 0.01 ppm
  • 0.1 ppm
  • 1 ppm
DiffusionView BTYQ-MS104K-S2
BTYQ-MS400-SPortable Gas Detectors
  • 0–10
  • 0–100
  • 0–500
  • 0–2,000
  • 0.01 ppm
  • 0.01 ppm
  • 0.1 ppm
  • 1 ppm
Diffusion (standard) or Pump (standard)View BTYQ-MS400-S
BTYQ-MS600-SPortable Gas Detectors
  • 0–10
  • 0–100
  • 0–500
  • 0–2,000
  • 0.001 ppm
  • 0.01 ppm
  • 0.1 ppm
  • 0.1 ppm
PumpView BTYQ-MS600-S
BTYQ-MS600-S1Portable Gas Detectors
  • 0–10
  • 0–100
  • 0–500
  • 0–2,000
  • 0.001 ppm
  • 0.01 ppm
  • 0.1 ppm
  • 0.1 ppm
PumpView BTYQ-MS600-S1
BTYQ-MS600-S2Portable Gas Detectors
  • 0–10
  • 0–100
  • 0–500
  • 0–2,000
  • 0.001 ppm
  • 0.01 ppm
  • 0.1 ppm
  • 0.1 ppm
PumpView BTYQ-MS600-S2
BTYQ-PTM600-STransportable Gas Detection Systems
  • 0–10
  • 0–100
  • 0–500
  • 0–2,000
  • 0.001 ppm
  • 0.01 ppm
  • 0.1 ppm
  • 0.1 ppm
PumpView BTYQ-PTM600-S
BTYQ-PTM600-S2Transportable Gas Detection Systems
  • 0–10
  • 0–100
  • 0–500
  • 0–2,000
  • 0.01 ppm
  • 0.01 ppm
  • 0.1 ppm
  • 1 ppm
DiffusionView BTYQ-PTM600-S2
GTYQ-MIC-500SFixed Gas Detectors
  • 0–10
  • 0–50
  • 0–100
  • 0–200
  • 0–10,000
  • 0–20,000
  • 0–50,000
  • 0.001 ppm
  • 0.01 ppm
  • 0.01 ppm
  • 0.1 ppm
  • 1 ppm
  • 1 ppm
  • 1 ppm
DiffusionView GTYQ-MIC-500S
GTYQ-MIC-500S-CBFixed Gas Detectors
  • 0–10
  • 0–100
  • 0–500
  • 0–2,000
  • 0.01 ppm
  • 0.01 ppm
  • 0.1 ppm
  • 1 ppm
DiffusionView GTYQ-MIC-500S-CB
GTYQ-MIC-600Fixed Gas Detectors
  • 0–10
  • 0–50
  • 0–100
  • 0–2,000
  • 0–10,000
  • 0.001 ppm
  • 0.01 ppm
  • 0.01 ppm
  • 0.1 ppm
  • 1 ppm
DiffusionView GTYQ-MIC-600
GTYQ-MIC-600-CBFixed Gas Detectors
  • 0–10
  • 0–100
  • 0–500
  • 0–2,000
  • 0.01 ppm
  • 0.01 ppm
  • 0.1 ppm
  • 1 ppm
DiffusionView GTYQ-MIC-600-CB

mg/m3 ranges

H2S measuring ranges and resolution by model (mg/m3)
Product modelProduct categoryMeasuring rangeResolutionSamplingProduct link
TH-2000-OUGas Monitoring and Analysis Systems
  • 0–10
  • 0.01 mg/m3
DiffusionView TH-2000-OU

Each row lists the H2S ranges a model can be configured with. The sensor combination and range for your unit are set when the order is confirmed.

Engineering Resources

technical guideHigh H₂S Peak, Low TWA: What to Check Next
Read
APPLICATION NOTEWastewater H₂S Monitoring: Setting Up the Gas Sampling System for Humid Tank Air
Read application note
ENGINEERING GUIDEHow to Define an Industrial Gas Leak Detection Project
Read guide

Gas detection questions

Define the H2S detection requirement

Provide the required unit and range, monitoring task, sampling method, deployment type, operating environment, applicable standard or jurisdiction, and any other gases that must be monitored.

Compare the options or discuss the requirement.

Send the gases, ranges and monitoring task. Our sales engineers confirm the configuration and reply with a quotation.